Skip to content
FaultCrate

This is an open preview: every record can be read without an account.

GMC Yukon XL 2000–2006

GMC Yukon XLModel years 2000–2006

Change vehicle →
Clear the search
2 conditions added

The vehicle (where a record says)

A record is under an engine, a drive or a series only where it says so: the characters of the vehicle identification number filed with a complaint, its text, or what its document says it applies to. A record that does not say is kept as "not stated". The filed numbers and the documents do not tell 4WD from AWD.

Common on this vehicle:Gauge or instrument faultWarning lightLoss of engine power, no accelerationSmoke or fireAir conditioning or heaterStalls or shuts offLeakDoes not start

Record by record

9 records state a cause or a remedy. Each record is shown as short labels in the order fault → finding the cause → correction. Press a label to narrow to the records that state it.

A ribbon is as wide as the records that state both of its ends (only the commonest are drawn). A record that names several symptoms or components runs through each. Orange is records that say the fault came back or was not fixed. Results come from owners’ reports only; one that does not say is “result not stated”. None of this is a likelihood of a cause or a rate at which work succeeds.

Read the records one by one (9)

Known issuesHVAC blower motor resistor module / connector overheating2

  1. Owner complaint2004 GMC YUKON XL 1500 ・ 2015-01-17

    Blower motor resistor failed; no air or heat for 3 years

    1. 1Fault

    2. 2Finding the cause

    3. 3CorrectionNot repaired

      SO NOT YEARS LATER STILL CAN'T FIX IT..CAN'T FIND THE RESISTOR AND NOW I HAVE NO AIR NO HEAT FOR 3 YEARS NOW. *TR

      What the documents say to do

      HVAC blower motor resistor module / connector overheating

      Repair

      1. Dealers install a new blower motor resistor and resistor module connector.
      2. Cut the wires back far enough to remove any melted insulation.

      Caution

      • The connector must be replaced even if it was replaced in an earlier repair.
    Read the sentences of the record
    Remedy
    SO NOT YEARS LATER STILL CAN'T FIX IT..CAN'T FIND THE RESISTOR AND NOW I HAVE NO AIR NO HEAT FOR 3 YEARS NOW. *TR
  2. Owner complaint2006 GMC YUKON XL 1500 ・ 2014-07-01

    Ventilation system malfunction with blower continuing to run when vehicle is off

    1. 1Fault

    2. 2Finding the cause

      Not stated

    3. 3Correction

      AS A RESULT, THE CONTACT HAD TO DISCONNECT THE POWER TO THE BLOWER.

      What the documents say to do

      HVAC blower motor resistor module / connector overheating

      Repair

      1. Dealers install a new blower motor resistor and resistor module connector.
      2. Cut the wires back far enough to remove any melted insulation.

      Caution

      • The connector must be replaced even if it was replaced in an earlier repair.
    Read the sentences of the record
    Fault
    THE CONTACT STATED THAT THE VENTILATION SYSTEM MALFUNCTIONED PREVENTING THE CONTACT FROM TURNING THE A/C AND OR HEATER ON. (2 more)
    Remedy
    AS A RESULT, THE CONTACT HAD TO DISCONNECT THE POWER TO THE BLOWER.
    Inspection
    THE VEHICLE WAS TAKEN TO AN AUTHORIZED DEALER WHO DIAGNOSED THAT THE RESISTOR MODULE CONNECTOR AND BLOWER NEEDED TO BE REPLACED.

Known issuesShift lever position indicator in the instrument cluster may not illuminate (FMVSS 102) - recall 05V-0551

  1. Owner complaint2005 GMC YUKON XL 1500 ・ 2014-08-15

    A/C blower runs at highest setting; gear indicator light dimmed

    1. 1Fault

    2. 2Finding the cause

      Not stated

    3. 3Correction

      THE BLOWER DID NOT STOP RUNNING UNTIL MY HUSBAND REMOVED THE FUSE.

      What the documents say to do

      Shift lever position indicator in the instrument cluster may not illuminate (FMVSS 102) - recall 05V-055

      Repair

      1. Dealers reprogram the instrument panel cluster.
      2. Prepare the vehicle for instrument panel cluster (IPC) reprogramming, then program the IPC using TIS data version 2.25.
    Read the sentences of the record
    Fault
    YESTERDAY I STARTED MY VEHICLE AND TURNED ON THE A/C. THE A/C BLOWER WAS BLOWING AT THE HIGHEST SETTING REGARDLESS OF THE CONTROL SETTING. (1 more)
    Remedy
    THE BLOWER DID NOT STOP RUNNING UNTIL MY HUSBAND REMOVED THE FUSE.

ELECTRICAL SYSTEM6

  1. Owner complaint2005 GMC YUKON DENALI XL ・ 2007-03-09

    Transmission overheating message, cooling system and electrical issues on Yukon Denali XL

    1. 1Fault

    2. 2Finding the cause

    3. 3Correction

    Read the sentences of the record
    Fault
    INITIALLY MY HUSBAND AND I NOTICED THE SEAT POSITION MEMORY WAS FAULTY. (2 more)
    Remedy
    LATER THAT DAY I FIND OUT THAT MY LESS THAN TWO YEAR OLD TRUCK COSTING ABOUT $50,000 NEEDED A NEW RADIATOR AND COOLANT SYSTEM, REPLACED RADIATOR HOSES UPPER AND LOWER,HEATER HOSES, REPLACED COOLANT JUG, REPLACED THERMOSTAT, REPLACE BYPASS HOSE AND TRUCK NEEDED AN EXTENSIVE ENGINE BLOCK COOLING FLUSH, FURTHER INDICATING THAT THE TRANSMISSION AND RADIATOR FLUID MIXED - TOTALING $2,100.
  2. Owner complaint2002 GMC YUKON XL 1500 ・ 2006-06-26

    Battery leaks battery acid and causes corrosion, warranty denied

    1. 1Fault

    2. 2Finding the cause

    3. 3Correction

      Not stated

    Read the sentences of the record
    Consequence
    THIS IS THE 2ND TIME IT HAS LEAKED, THE PROPERTY DAMAGE MARKED BELOW IS ?- I DO NOT KNOW WHAT ELSE IS DAMAGED BELOW OR AROUND THE SPOT WHERE THE BATTERY RESIDES? *NM
  3. Owner complaint2003 GMC YUKON XL ・ 2006-06-06

    Loud grinding noise and bang at highway speeds, stall with white smoke, recurring

    1. 1Fault

    2. 2Finding the cause

      Not stated

    3. 3Correction

    Read the sentences of the record
    Fault
    DT*: THE CONTACT STATED ON THREE OCCASIONS WHILE DRIVING AT HIGHWAY AND FREEWAY SPEEDS OF 30- 75 MPH (= 48.3–120.7 km/h) THE VEHICLE MADE A LOUD GRINDING NOISE FOLLOWED BY ANOTHER LOUD BANG. (1 more)
    Remedy
    THE ENTIRE A/C WAS REPLACED ON TWO OCCASIONS. (2 more)
  4. Owner complaint2004 GMC YUKON DENALI XL ・ 2015-07-08

    Multiple electrical issues including instrument cluster and stall condition

    1. 1Fault

    2. 2Finding the cause

    3. 3Correction

      Not stated

    Read the sentences of the record
    Fault
    ELECTRICAL CLUSTER ALSO GOING BAD AND INSTRUMENTS NOT WORKING, AIR CONDITIONING ELECTRICAL PROBLEM , WILL BLOW COLD OUT OF ALL BUT TWO VENTS, WHERE IT BLOWS 90 DEGREES. (1 more)
    Inspection
    DEALER SAID NO ERROR CODES TEST DROVE FOR A WEEK TO GET TO REPRODUCE STALL DRIVING, RETURNED TO ME SAYING CAN'T DIAGNOSE.
  5. Owner complaint2005 GMC YUKON XL 1500 ・ 2011-11-26

    Front cabin in-dash fire while parked

    1. 1Fault

    2. 2Finding the cause

    3. 3Correction

  6. Owner complaint2003 GMC YUKON XL ・ 2005-08-03

    Air conditioner squealing and rattling noise; compressor failure after recycling switch replacement

    1. 1Fault

    2. 2Finding the cause

    3. 3Correction

    Read the sentences of the record
    Fault
    I ALSO NOTICED A RATTLING NOISE UPON ACCELERATION WHILE THE AC WAS ON.
    Inspection
    I TOOK IT TO THE DEALER IN MICHIGAN AND AT FIRST NOTHING WAS FOUND.

1 owner complaints have no classified sentences yet, so their causes and repairs are not picked out. Their text is in the list of records.