GMC Yukon 2000–2006
Common on this vehicle:Air conditioning or heaterSmoke or fire
Record by record
9 records state a cause or a remedy. Each record is shown as short labels in the order fault → finding the cause → correction. Press a label to narrow to the records that state it.
Component named as the cause
A ribbon is as wide as the records that state both of its ends (only the commonest are drawn). A record that names several symptoms or components runs through each. Orange is records that say the fault came back or was not fixed. Results come from owners’ reports only; one that does not say is “result not stated”. None of this is a likelihood of a cause or a rate at which work succeeds.
Read the records one by one (9)
Known issuesBlower motor inoperative after blower control module replacement (auto HVAC)1
Manufacturer communication2003 GMC YUKON ・ 2012-05-02
Blower Motor Inoperative After Control Module Replacement
1Fault
2Finding the cause
3Correction
What the documents say to do
Blower motor inoperative after blower control module replacement (auto HVAC)Repair
- Replace module PN 89019351 with the updated Blower Motor Control Module, GM PN 19260762.
Read the sentences of the record
- Remedy
- GM: BLOWER INOPERATIVE AFTER CONTROL MODULE REPLACEMENT. THIS MAY OCCUR IF THE SPEED IS SET TO ANY SPEED POSITION, EXCEPT FOR LOW, WHEN THE KEY IS TURNED OFF. UPON NEST KEY UP, THE BLOWER MOTOR MAY BE INOPERATIVE. ALSO INCLUDED MODEL CHEVROLET TRAILBLAZER XL MODEL YEARS 2003-2007. *JS
Known issuesHVAC blower motor resistor module / connector overheating1
Manufacturer communication2003–2006 GMC YUKON ・ 2011-06-27
General Motors HVAC Blower Service Campaign
1Fault
2Finding the cause
3Correction
What the documents say to do
HVAC blower motor resistor module / connector overheatingRepair
- Dealers install a new blower motor resistor and resistor module connector.
- Cut the wires back far enough to remove any melted insulation.
Caution
- The connector must be replaced even if it was replaced in an earlier repair.
Read the sentences of the record
- Remedy
- GENERAL MOTORS SERVICE CAMPAIGN: SEE DOCUMENT SEARCH BUTTON FOR OWNER LETTER. THE HVAC BLOWER MAY NOT WORK AT CERTAIN FUNCTIONS OR MAY BECOME INOPERABLE. THERE COULD BE A BURNING SMELL OR SMOKE. *RM UPDATED 4/6/12. *PE
EQUIPMENT4
Manufacturer communication2003–2006 GMC YUKON DENALI ・ 2012-04-10
Blower Motor Inoperativity with Key Off
1Fault
2Finding the cause
3Correction
Read the sentences of the record
- Remedy
- BUICK/CADILLAC/CHEVROLET/GMC/OLDSMOBILE: IF BLOWER MOTOR IS SET TO ANY SPEED POSITION AND WHEN KEY IS OFF, IT BECOMES INOPERATIVE AND MAY STILL BE INOPERATIVE AFTER KEY IS TURNED ON. *PE UPDATED ON 5/1/12. *JS
Manufacturer communication2004–2006 GMC YUKON ・ 2005-11-04
Blower Motor Speed Loss Except High Speed or Inoperative
1Fault
2Finding the cause
3Correction
Read the sentences of the record
- Remedy
- EI05082 - LOSS OF BLOWER MOTOR SPEEDS EXCEPT FOR HIGH SPEED OR INOPERATIVE. *TT UPDATED. *KB UPDATED *KB
Manufacturer communication2003–2004 GMC YUKON ・ 2004-10-08
Repeat HVAC Blower Motor Failure
1Fault
2Finding the cause
3Correction
Read the sentences of the record
- Remedy
- REPEAT HVAC BLOWER MOTOR FAILURE. *TT
Manufacturer communication2000–2002 GMC YUKON DENALI ・ 2004-07-13
Fan blower motor continues to run after key off; A/C control head locking
1Fault
2Finding the cause
3Correction
Read the sentences of the record
- Remedy
- THE FAN BLOWER MOTOR CONTINUES TO RUN AFTER THE KEY HAS BEEN TURNED OFF OR THE A/C CONTROL HEAD LOCKING UP. *TT
VISIBILITY3
Manufacturer communication2004–2005 GMC YUKON ・ 2005-10-25
Blower Motor Inoperative at Low Ambient Temperatures
1Fault
2Finding the cause
3Correction
Read the sentences of the record
- Remedy
- BLOWER MOTOR INOPERATIVE AT LOW AMBIENT TEMPERATURES. *TT
Manufacturer communication2003–2005 GMC YUKON ・ 2005-01-10
HVAC Blower Motor Inoperative or Stays Running
1Fault
2Finding the cause
3Correction
Read the sentences of the record
- Remedy
- HVAC BLOWER MOTOR INOPERATIVE OR STAYS RUNNING. *TT
Manufacturer communication2004 GMC YUKON ・ 2003-12-01
HVAC Blower Motor May Run Continuously After Vehicle Is Turned Off
1Fault
2Finding the cause
3Correction
HVAC BLOWER MOTOR MAY RUN CONTINUOUSLY AFTER VEHICLE IS TURNED OFF. *TT
Read the sentences of the record
- Remedy
- HVAC BLOWER MOTOR MAY RUN CONTINUOUSLY AFTER VEHICLE IS TURNED OFF. *TT