Skip to content
FaultCrate

This is an open preview: every record can be read without an account.

GMC YukonModel years 2000–2006

Change vehicle →

← All known issues

Heating and air conditioningModel years 2003–2006Manufacturer

Blower motor inoperative after blower control module replacement (auto HVAC)

2003 - 2006 GMC Yukon Models with Auto HVAC (and Escalade, Avalanche, Suburban, Tahoe, Silverado/Sierra Classic, TrailBlazer, Envoy and others)

On vehicles with Auto HVAC, in some rare cases the blower motor may be inoperative after the Blower Motor Control Module is replaced with part number 89019351. It may occur if the blower speed is set to any position except low when the key is turned off; on the next key up, the blower may be inoperative.

How to decide

If present, replace PN 89019351 with the updated GM PN 19260762

Watch out

PIT5141B updates the part numbers; discard PIT5141A

Parts

Updated blower motor control module, GM PN 19260762

Check3

  • It covers the 2003 - 2006 GMC Yukon Models among others, with Auto HVAC.NHTSA
  • The same PI also lists the 2003 - 2006 Cadillac Escalade Models and Chevrolet Avalanche, Suburban and Tahoe, and the 2003 - 2007 Chevrolet Silverado Classic and GMC Sierra Classic.NHTSA
  • Check whether the Blower Motor Control Module was earlier replaced with PN 89019351. If the blower speed is set to any position except low when the key is turned off, the blower motor may be inoperative on the next key up.NHTSA

Decide1

If this condition is present, replace the previously installed Blower Motor Control Module (PN 89019351) with the updated module, GM PN 19260762.NHTSA

Steps

None of the documents at hand gives the manufacturer's procedure.

Cautions and risks1

  • PIT5141B (April 2012) superseded the earlier version to update part numbers; PIT5141A is to be discarded.NHTSA

What it needs

Parts
  • Updated Blower Motor Control Module, GM PN 19260762 (replacing the previously installed PN 89019351).NHTSA

Part numbers printed in the document

The numbers are as the document prints them. The name and the replacing number are what the pages of GMPartsGiant, a reseller of genuine parts and not GM, state. Aftermarket equivalents are not checked here (the links only search by number). Confirm the fit for the vehicle (VIN) before ordering.

Only what the documents and the pages read state; what is not listed is not thereby not needed.

Applies to

  • The bulletin covers 2003 - 2006 GMC Yukon models.
  • It applies to vehicles with Auto HVAC.
See the evidence (1 documents, 5 passages)
DocumentPublisherDate
[1]PIT5141B: Blower Motor Inoperative After Blower Control Module Replacement ↗
ManufacturerGeneral Motors
2012-04-01
  • Applies toThe bulletin covers 2003 - 2006 GMC Yukon models.

    2003 - 2006 GMC Yukon Models— [1] Models
  • Applies toIt applies to vehicles with Auto HVAC.

    With Auto HVAC— [1] Models
  • First signsIn rare cases the blower motor may be inoperative after replacing the Blower Motor Control Module with part number 89019351.

    In some rare cases, after replacing the Blower Motor Control Module with part number 89019351, the blower motor may be inoperative.— [1] Condition
  • Why it happensIt may occur if the blower speed is set to any position except low when the key is turned off.

    This issue may occur if the blower motor speed is set to any speed position, except for low, when the key is turned off.— [1] Condition
  • RepairReplace module PN 89019351 with the updated Blower Motor Control Module, GM PN 19260762.

    replace the previously installed Blower Motor Control Module (PN 89019351) with the updated Blower Motor Control Module, GM PN 19260762.— [1] Recommendation

Records under this issue 1

Manufacturer communication 1

Look into the records of this issue (1)
List the records (1 that can be opened)

Records whose recall number, document number or text matches. Each line says why it matched.

Blower motor inoperative after blower control module replacement (auto HVAC) — 2000–2006 GMC Yukon | FaultCrate