Skip to content
FaultCrate

This is an open preview: every record can be read without an account.

GMC Yukon 2000–2006

GMC YukonModel years 2000–2006

Change vehicle →
Clear the search
2 conditions added

The vehicle (where a record says)

A record is under an engine, a drive or a series only where it says so: the characters of the vehicle identification number filed with a complaint, its text, or what its document says it applies to. A record that does not say is kept as "not stated". The filed numbers and the documents do not tell 4WD from AWD.

Common on this vehicle:NoiseWarning lightCorrosion or rustLeakMisfire or rough idleAir conditioning or heaterReduced brakingLights (headlights, turn signals)

Record by record

28 records state a cause or a remedy. Each record is shown as short labels in the order fault → finding the cause → correction. Press a label to narrow to the records that state it.

A ribbon is as wide as the records that state both of its ends (only the commonest are drawn). A record that names several symptoms or components runs through each. Orange is records that say the fault came back or was not fixed. Results come from owners’ reports only; one that does not say is “result not stated”. None of this is a likelihood of a cause or a rate at which work succeeds.

Read the records one by one (20)

Known issuesA/C blows warm at extended idle (6.0L: auxiliary electric cooling fan)1

  1. Manufacturer communication2000–2002 GMC C/K UTILITY MODELS (YUKON) ・ 2001-12-01

    A/C not cold enough or blows warm at extended idle (6.0L): auxiliary electric cooling fan (bulletin 01-01-39-004)

    1. 1Fault

    2. 2Finding the cause

      Not stated

    3. 3Correction

      Repair

      • The condition is A/C not cold enough, or A/C blowing warm air with the vehicle at extended idle; the correction is to install an auxiliary electric cooling fan.
    Read the sentences of the record

    From the manufacturer’s document

    • Applies to:Bulletin 01-01-39-004 applies to 2000-02 Chevrolet and GMC C/K Utility Models and the 2002 Cadillac Escalade with the 6.0L engine (VINs U, N; RPOs LQ4, LQ9).
    • Repair:The condition is A/C not cold enough, or A/C blowing warm air with the vehicle at extended idle; the correction is to install an auxiliary electric cooling fan.

    Open this issue of GM TechLink ↗ The points above are read from an article of TechLink, GM’s monthly publication for dealership technicians. The article itself is not reproduced here.

    Remedy
    Bulletins – November 2001 01-01-39-004; A/C Not Cold Enough, A/C Blows Warm Air with Vehicle at Extended Idle (Install Auxiliary Electric Cooling Fan); 2000-02 Chevrolet and GMC C/K Utility Models, 2002 Cadillac Escalade, with 6.0L Engine (VINs U, N – RPOs LQ4, LQ9) A/C Not Cold Enough, A/C Blows Warm Air with Vehicle at Extended Idle (Install Auxiliary Electric Cooling Fan)

Known issuesIntermittent battery drain from a sticking A/C compressor relay1

  1. Manufacturer communication2000–2002 GMC FULL SIZE PICKUPS AND UTILITY MODELS (YUKON) ・ 2002-01-01

    Intermittent battery drain from a sticking A/C compressor relay

    1. 1Fault

      • The drain may occur overnight.
    2. 2Finding the cause

      Possible causes

      • The A/C compressor relay may stick, causing the battery to drain.
    3. 3Correction

      Repair

      • The current recommendation is to replace the relay.
    Read the sentences of the record

    From the manufacturer’s document

    • Applies to:Owners of 2000-02 full size pickups and utility models may comment on an intermittent battery drain.
    • Condition:The drain may occur overnight.
    • Cause:The A/C compressor relay may stick, causing the battery to drain.
    • Repair:The current recommendation is to replace the relay.

    Open this issue of GM TechLink ↗ The points above are read from an article of TechLink, GM’s monthly publication for dealership technicians. The article itself is not reproduced here.

    Remedy
    Intermittent Battery Drain Owners of 2000-02 full size pickups and utility models may comment on an intermittent battery drain. This drain may occur overnight. The A/C compressor relay may stick causing the battery to drain. The current recommendation is to replace the relay.

EQUIPMENT13

  1. Owner complaint2002 GMC YUKON ・ 2005-11-21

    A/C compressor noise on startup and sunroof closure issue

    1. 1Fault

    2. 2Finding the cause

    3. 3Correction

    Read the sentences of the record
    Fault
    *TS ***NO ANSWER REQUIRED*** THE A/C COMPRESSOR WAS NOISY ON STARTUP. (1 more)
    Remedy
    THE DEALER HAD TO INSTALL A NEW SUNROOF FRAME. *NM
  2. Owner complaint2002 GMC YUKON ・ 2005-10-31

    Rear side mirrors with hairline cracks on both sides

    1. 1Fault

    2. 2Finding the cause

    3. 3Correction

    Read the sentences of the record
    Fault
    REAR SIDE MIRROR ON BOTH DRIVER AND PASSENGER SIDE HAVE HAIRLINE CRACKS.
    Cause
    I BELIEVE THE MIRRORS ARE TOO THIN TO HANDLE THE DEFROST OPTIONS ON THE MIRRORS.
  3. Manufacturer communication2000–2002 GMC YUKON ・ 2005-02-17

    Loss of Heating Ventilation Air Conditioning System Mode and Temperature Control

    1. 1Fault

    2. 2Finding the cause

      Not stated

    3. 3Correction

      LOSS OF HEATING VENTILATION AIR CONDITIONING. SYSTEM MODE AND OR TEMPERATURE CONTROL. *EH

    Read the sentences of the record
    Remedy
    LOSS OF HEATING VENTILATION AIR CONDITIONING. SYSTEM MODE AND OR TEMPERATURE CONTROL. *EH
  4. Manufacturer communication2000–2005 GMC YUKON DENALI ・ 2005-01-10

    A/C Low Pressure Switch Diagnosis with Kent Moore Tool GE-47742

    1. 1Fault

    2. 2Finding the cause

      Not stated

    3. 3Correction

      DIAGNOSTIC INFORMATION TO ACCURATELY DIAGNOSE A/C LOW PRESSURE SWITCH USING NEW KENT MOORE SPECIAL TOOL GE-47742. *TT

    Read the sentences of the record
    Remedy
    DIAGNOSTIC INFORMATION TO ACCURATELY DIAGNOSE A/C LOW PRESSURE SWITCH USING NEW KENT MOORE SPECIAL TOOL GE-47742. *TT
  5. Manufacturer communication2000–2005 GMC YUKON ・ 2004-10-04

    A/C Low Pressure Switch Diagnostic Tool Communication

    1. 1Fault

    2. 2Finding the cause

    3. 3Correction

      AIR CONDITIONER (A/C) LOW PRESSURE SWITCH DIAGNOSTIC TOOL. CURRENTLY THE A/C LOW PRESSURE SWITCH OPEN/CLOSE PRESSURES CANNOT BE ACCURATELY DETERMINED BY MEASURING PRESSURE AT THE LOW SIDE SERVICE PORT. *TT

    Read the sentences of the record
    Remedy
    AIR CONDITIONER (A/C) LOW PRESSURE SWITCH DIAGNOSTIC TOOL. CURRENTLY THE A/C LOW PRESSURE SWITCH OPEN/CLOSE PRESSURES CANNOT BE ACCURATELY DETERMINED BY MEASURING PRESSURE AT THE LOW SIDE SERVICE PORT. *TT
  6. Manufacturer communication2000–2002 GMC YUKON DENALI ・ 2004-07-13

    Fan blower motor continues to run after key off; A/C control head locking

    1. 1Fault

    2. 2Finding the cause

    3. 3Correction

      THE FAN BLOWER MOTOR CONTINUES TO RUN AFTER THE KEY HAS BEEN TURNED OFF OR THE A/C CONTROL HEAD LOCKING UP. *TT

    Read the sentences of the record
    Remedy
    THE FAN BLOWER MOTOR CONTINUES TO RUN AFTER THE KEY HAS BEEN TURNED OFF OR THE A/C CONTROL HEAD LOCKING UP. *TT
  7. Manufacturer communication2001–2004 GMC YUKON DENALI ・ 2004-06-09

    Rear Air Conditioning HVAC Blower Motor Control Module Information

    1. 1Fault

    2. 2Finding the cause

      Not stated

    3. 3Correction

      REAR AIR CONDITIONING HVAC BLOWER MOTOR CONTROL MODULE INFORMATION. *TT

    Read the sentences of the record
    Remedy
    REAR AIR CONDITIONING HVAC BLOWER MOTOR CONTROL MODULE INFORMATION. *TT
  8. Manufacturer communication2002–2004 GMC YUKON DENALI ・ 2004-03-02

    Underhood Air Conditioner Rattle Noise and Performance Loss

    1. 1Fault

    2. 2Finding the cause

      Not stated

    3. 3Correction

      UNDERHOOD AIR CONDITIONER RATTLE NOISE HEARD ON ACCELERATION OR A SUDDEN LOSS OF AIR CONDITIONER SYSTEM PERFORMANCE. *TT THIS BULLETIN REPLACES 03-01-38-019 DATED 11-01-2003. TO INCLUDE VARIOUS MODLES INCLUDING 2002-2004 COMMERCIAL UPFITTER CHASSIS VEHICLES. *TT

    Read the sentences of the record
    Remedy
    UNDERHOOD AIR CONDITIONER RATTLE NOISE HEARD ON ACCELERATION OR A SUDDEN LOSS OF AIR CONDITIONER SYSTEM PERFORMANCE. *TT THIS BULLETIN REPLACES 03-01-38-019 DATED 11-01-2003. TO INCLUDE VARIOUS MODLES INCLUDING 2002-2004 COMMERCIAL UPFITTER CHASSIS VEHICLES. *TT
  9. Manufacturer communication2001–2004 GMC YUKON ・ 2003-11-20

    Rear Air Conditioning HVAC Blower Motor Control Module Information

    1. 1Fault

    2. 2Finding the cause

      Not stated

    3. 3Correction

      REAR AIR CONDITIONING HVAC BLOWER MOTOR CONTROL MODULE INFORMATION. SERVICE VME. SIT BULLETIN 1455584. *TT (THIS BULLETIN REPLACES PI01428A DATED 11-18-03). *TT

    Read the sentences of the record
    Remedy
    REAR AIR CONDITIONING HVAC BLOWER MOTOR CONTROL MODULE INFORMATION. SERVICE VME. SIT BULLETIN 1455584. *TT (THIS BULLETIN REPLACES PI01428A DATED 11-18-03). *TT
  10. Manufacturer communication2002–2003 GMC YUKON DENALI ・ 2003-11-19

    Air Conditioning Compressor Belt or Tensioner Flutter Noise Service

    1. 1Fault

    2. 2Finding the cause

    3. 3Correction

      AIR CONDITIONING COMPRESSOR BELT OR TENSIONER JUMPS OR FLUTTERS CAUSING A RATTLE NOISE. SERVICE VME. *TT

    Read the sentences of the record
    Remedy
    AIR CONDITIONING COMPRESSOR BELT OR TENSIONER JUMPS OR FLUTTERS CAUSING A RATTLE NOISE. SERVICE VME. *TT
  11. Manufacturer communication2000–2003 GMC YUKON ・ 2003-03-28

    Air Conditioner Not Cold Enough, Blows Warm Air at Extended Idle

    1. 1Fault

    2. 2Finding the cause

      Not stated

    3. 3Correction

      AIR CONDITIONER NOT COLD ENOUGH, AIR CONDITIONER BLOWS WARM AIR WITH VEHICLE AT EXTENDED IDLE. *TT

    Read the sentences of the record
    Remedy
    AIR CONDITIONER NOT COLD ENOUGH, AIR CONDITIONER BLOWS WARM AIR WITH VEHICLE AT EXTENDED IDLE. *TT
  12. Manufacturer communication2000–2002 GMC YUKON ・ 2002-02-25

    A/C Not Cold Enough or Blows Warm Air at Extended Idle

    1. 1Fault

    2. 2Finding the cause

      Not stated

    3. 3Correction

      INFORMATION REGARDING A/C NOT COLD ENOUGH, A/C BLOWS WARM AIR WITH VEHICLE AT EXTENDED IDLE. *YH

    Read the sentences of the record
    Remedy
    INFORMATION REGARDING A/C NOT COLD ENOUGH, A/C BLOWS WARM AIR WITH VEHICLE AT EXTENDED IDLE. *YH
  13. Owner complaint2002 GMC YUKON ・ 2010-12-01

    Air conditioning and heating operate without ignition on 2002 GMC Yukon

    1. 1Fault

    2. 2Finding the cause

    3. 3Correction

    Read the sentences of the record
    Fault
    THE CONTACT STATED THAT A MONTH AGO THE VEHICLE WAS COMPLETELY TURNED OFF WITHOUT THE KEY IN THE IGNITION AND THE AIR CONDITIONER CAME ON FULL BLAST. (1 more)
    Inspection
    THE VEHICLE WAS TAKEN TO A LOCAL MECHANIC WHO STATED THAT THE FAILURE WAS CAUSED BY CORRODED WIRES UNDERNEATH THE DASHBOARD.

ELECTRICAL SYSTEM2

  1. Owner complaint2002 GMC YUKON ・ 2004-12-28

    Front defrost blower runs at high speed and will not shut off

    1. 1Fault

    2. 2Finding the cause

      Not stated

    3. 3Correction

      AT THIS TIME I HAVE PULLED THE FUSE TO KEEP THE FAN FROM BLOWING BUT IT'S TOO COLD TO BE DRIVING WITH NO HEAT OR DEFROST IN THE CAR.

    Read the sentences of the record
    Fault
    DEC 24 2004 I RETURNED TO MY PARKED CAR AND STARTED THE ENGINE, THE FRONT DEFROST BLOWERS WENT TO HIGH SPEED AND WOULD NOT SHUT OFF. (1 more)
    Remedy
    AT THIS TIME I HAVE PULLED THE FUSE TO KEEP THE FAN FROM BLOWING BUT IT'S TOO COLD TO BE DRIVING WITH NO HEAT OR DEFROST IN THE CAR.
  2. Owner complaint2002 GMC YUKON ・ 2005-07-15

    Air conditioner loud noise with acceleration, then blowing hot air

    1. 1Fault

    2. 2Finding the cause

    3. 3Correction

    Read the sentences of the record
    Fault
    AIR CONDITIONER BEGAN MAKING LOUD NOISE WITH ACCELARATION, THAN WITHIN A FEW MOMENTS BEGAN BLOWING HOT AIR.

TIRES1

  1. Manufacturer communication2001–2004 GMC YUKON DENALI ・ 2018-05-21(1 earlier editions of this document folded here)

    Wheel and Tire Mounting and Balancing Notification

    1. 1Fault

      • Customers may say the HVAC blower motor does not work or that no air flows from the vents; it may be intermittent.
    2. 2Finding the cause

      Possible causes

      • One possible cause is the contacts in the HVAC junction block(s) at the right side of the instrument panel.

      Steps to confirm (in the document’s order)

      1. With the ignition on and the blower running, apply light hand pressure to the junction block connectors and see whether the movement affects blower operation.
      2. On junction block X4, locate Pin A6, Circuit 754.
      3. On X4, perform a pin drag test with test probe J-35616-2A (GY).
      4. On junction block X6, locate Pin A, Circuit 542.
      5. On X6, perform a pin drag test with test probe J-35616-42 (RD).
    3. 3Correction

      Repair

      • If the terminal fails the pin drag test, replace the terminal for Pin A6, referring to Junction Block - Right I/P X4 in SI.

      Parts

      • Terminals: 12191812/19 Junction Block X4 Terminal/Tray; 12084590/3 Junction Block X6 Terminal/Tray.

      Part numbers printed in the document

      The numbers are as the document prints them. The name and the replacing number are what the pages of GMPartsGiant, a reseller of genuine parts and not GM, state. Aftermarket equivalents are not checked here (the links only search by number). Confirm the fit for the vehicle (VIN) before ordering.

      Caution

      • Do not replace the HVAC blower motor assembly to correct this condition.
    Read the sentences of the record

    From the manufacturer’s document

    • Applies to:Applies to 2008-2013 GMC Yukon models (note: later than the years this service covers).
    • Applies to:Vehicles built prior to November 1, 2012 are covered.
    • Condition:Customers may say the HVAC blower motor does not work or that no air flows from the vents; it may be intermittent.
    • Cause:One possible cause is the contacts in the HVAC junction block(s) at the right side of the instrument panel.
    • Caution:Do not replace the HVAC blower motor assembly to correct this condition.
    • Confirm:With the ignition on and the blower running, apply light hand pressure to the junction block connectors and see whether the movement affects blower operation.
    • Confirm:On junction block X4, locate Pin A6, Circuit 754.
    • Confirm:On X4, perform a pin drag test with test probe J-35616-2A (GY).
    • Repair:If the terminal fails the pin drag test, replace the terminal for Pin A6, referring to Junction Block - Right I/P X4 in SI.
    • Confirm:On junction block X6, locate Pin A, Circuit 542.
    • Confirm:On X6, perform a pin drag test with test probe J-35616-42 (RD).
    • Parts:Terminals: 12191812/19 Junction Block X4 Terminal/Tray; 12084590/3 Junction Block X6 Terminal/Tray.

    Open the manufacturer’s document (PDF) ↗ The points above were read from this document.

    Remedy
    This informational bulletin provides information on how to properly mount and balance wheels and tires on heavy duty truck models only

UNKNOWN OR OTHER1

  1. Manufacturer communication2000–2006 GMC YUKON ・ 2024-09-12(7 earlier editions of this document folded here)

    Heater-Vent-Air Conditioning Warm Air Issue

    1. 1Fault

      • The A/C blows warm or A/C performance is poor.
    2. 2Finding the cause

      Steps to confirm (in the document’s order)

      1. Record the A/C high and low pressures from actual A/C gauges, the high side sensor reading from GDS, and the A/C compressor duty cycle.
      2. Also record the outside temperature, humidity and vent temperature.
      3. With an automatic HVAC system, read the evaporator temperature sensor (if equipped), inside temperature sensor, outside temperature sensor and duct temperature sensors with the scan tool.
    3. 3Correction

      This Preliminary Information communication provides information to the technician about vehicles that the Heater-Vent-Air Conditioning blows warm air. Before calling General Motors Technical Assistance Center technician will need to have high and low pressures, outside temperature, humidity, and vent temperature.

    Read the sentences of the record

    From the manufacturer’s document

    • Applies to:Applies to all models, 2000 - 2024.
    • Condition:The A/C blows warm or A/C performance is poor.
    • Confirm:Record the A/C high and low pressures from actual A/C gauges, the high side sensor reading from GDS, and the A/C compressor duty cycle.
    • Confirm:Also record the outside temperature, humidity and vent temperature.
    • Confirm:With an automatic HVAC system, read the evaporator temperature sensor (if equipped), inside temperature sensor, outside temperature sensor and duct temperature sensors with the scan tool.

    Open the manufacturer’s document (PDF) ↗ The points above were read from this document.

    Remedy
    This Preliminary Information communication provides information to the technician about vehicles that the Heater-Vent-Air Conditioning blows warm air. Before calling General Motors Technical Assistance Center technician will need to have high and low pressures, outside temperature, humidity, and vent temperature.

VISIBILITY1

  1. Manufacturer communication2001–2006 GMC YUKON DENALI ・ 2017-12-22

    Rear Window Defroster Contact or Tabs Service Information

    1. 1Fault

    2. 2Finding the cause

      Not stated

    3. 3Correction

      Repair

      1. On 2007-2014 Tahoe, Suburban, Yukon and Escalade with moveable glass always replace the defroster tab (GM P/N 25916031) and the power connector (P/N 12034110); on all other vehicles reconnect the original defroster tab.
      2. Remove the rear defroster power connector and crimp a new one to the feed wire; the proper connector, P/N 12034110, is in the Packard Electrical Assortment, Tray 18, Position 5.
      3. Prepare the surface of the used defroster tab and the defroster buss bar with fine grain (500 grit) sandpaper or Emery cloth.
      4. Wipe the prepared contact area with Kent Automotive Acrysol (or equivalent) to remove residual oil or dirt.
      5. Heat the new connector on the buss bar surface to be soldered, holding the connector and defroster tab in place with long nose pliers.

      Part numbers printed in the document

      The numbers are as the document prints them. The name and the replacing number are what the pages of GMPartsGiant, a reseller of genuine parts and not GM, state. Aftermarket equivalents are not checked here (the links only search by number). Confirm the fit for the vehicle (VIN) before ordering.

      Parts

      • Silver solder: Radio Shack (The Source in Canada) 64-013, 0.022" diameter.
      • Solvent: P20005 Kent Automotive Acrysol Solvent (32 fl oz) 946 ml.

      Caution

      • Let the glass warm to the temperature inside the building; soldering creates a hot spot in the glass, so do not solder on cold glass.
      • Heating the glass excessively, or repeatedly without time to cool, may break the glass.
      • A silver-bearing solder must be used; do not attempt the repair with conventional tin/lead alloy solders.
    Read the sentences of the record

    From the manufacturer’s document

    • Applies to:Covers 2000-2015 GM passenger cars and trucks, excluding the 2015 Chevrolet Tahoe, Suburban, GMC Yukon and Cadillac Escalade.
    • Applies to:Vehicles must have the electric rear window defroster (RPO C49).
    • Repair:On 2007-2014 Tahoe, Suburban, Yukon and Escalade with moveable glass always replace the defroster tab (GM P/N 25916031) and the power connector (P/N 12034110); on all other vehicles reconnect the original defroster tab.
    • Caution:Let the glass warm to the temperature inside the building; soldering creates a hot spot in the glass, so do not solder on cold glass.
    • Caution:Heating the glass excessively, or repeatedly without time to cool, may break the glass.
    • Caution:A silver-bearing solder must be used; do not attempt the repair with conventional tin/lead alloy solders.
    • Repair:Remove the rear defroster power connector and crimp a new one to the feed wire; the proper connector, P/N 12034110, is in the Packard Electrical Assortment, Tray 18, Position 5.
    • Repair:Prepare the surface of the used defroster tab and the defroster buss bar with fine grain (500 grit) sandpaper or Emery cloth.
    • Repair:Wipe the prepared contact area with Kent Automotive Acrysol (or equivalent) to remove residual oil or dirt.
    • Repair:Heat the new connector on the buss bar surface to be soldered, holding the connector and defroster tab in place with long nose pliers.
    • Parts:Silver solder: Radio Shack (The Source in Canada) 64-013, 0.022" diameter.
    • Parts:Solvent: P20005 Kent Automotive Acrysol Solvent (32 fl oz) 946 ml.

    Open the manufacturer’s document (PDF) ↗ The points above were read from this document.

    Remedy
    This informational bulletin provide information for the technicians to repair the rear window defroster contact or tabs.

Showing 20 of the 28 you can open. Narrow the search to see the rest.

1 owner complaints have no classified sentences yet, so their causes and repairs are not picked out. Their text is in the list of records.