GMC Yukon 2000–2006
Common on this vehicle:Corrosion or rustAir conditioning or heaterSmoke or fire
Record by record
1 records state a cause or a remedy. Each record is shown as short labels in the order fault → finding the cause → correction. Press a label to narrow to the records that state it.
Component named as the cause
A ribbon is as wide as the records that state both of its ends (only the commonest are drawn). A record that names several symptoms or components runs through each. Orange is records that say the fault came back or was not fixed. Results come from owners’ reports only; one that does not say is “result not stated”. None of this is a likelihood of a cause or a rate at which work succeeds.
Read the records one by one (1)
Known issuesHVAC blower motor resistor module / connector overheating1
Owner complaint2004 GMC YUKON ・ 2016-08-22
Blower resistor module corrosion from water entry into HVAC system
1Fault
2Finding the cause
3CorrectionNot repaired
What the documents say to do
HVAC blower motor resistor module / connector overheatingRepair
- Dealers install a new blower motor resistor and resistor module connector.
- Cut the wires back far enough to remove any melted insulation.
Caution
- The connector must be replaced even if it was replaced in an earlier repair.
Read the sentences of the record
- Remedy
- THE VEHICLE WAS NOT REPAIRED.