GMC Yukon 2000–2006
Common on this vehicle:Air conditioning or heaterSmoke or fireLiftgate, rear glass or door lock
Records
Owner complaint 4Recall 0Manufacturer communication 1115 of 15 open without registering
Records per year (date of the record)
Owner complaintManufacturer communication
2003200520102015202020252026
The 15 records listed below, each on its date (a dot opens its record)
2003-11-192018-09-05
Owner complaintDate 2018-09-05
Passenger side under-dash area caught fire while driving
2006 GMC YUKON DENALI
THE PASSENGER SIDE UNDER DASH BORED CAUGHT ON FIRE. WILE DRIVING DOWN THE STREET IT STARTED TO SMOKE AND I SAW FLAM. I WAS ABLE TO PUT FLAM OUT AND LUCKY WAS A BLOCK FROM HOME. I PARKED IT TURNED IT OFF IT SEAMED LIKE THE FIRE WAS OUT AND
Owner complaintDate 2017-06-06
Air conditioner not operable and vehicle will not power off
2006 GMC YUKON
TL* THE CONTACT OWNS A 2006 GMC YUKON. THE CONTACT STATED THAT THE AIR CONDITIONER IN THE FRONT OF THE VEHICLE WAS NOT OPERABLE. THE VEHICLE WOULD NOT POWER OFF EVEN WHEN SHIFTED IN THE OFF POSITION. THE VEHICLE'S BATTERY MUST BE DISCONNECT
Owner complaintDate 2016-06-07
Blower motor stopped working while driving
2003 GMC YUKON
TL* THE CONTACT OWNS A 2003 GMC YUKON. WHILE DRIVING 65 MPH, THE BLOWER MOTOR STOPPED WORKING WITHOUT WARNING. THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC. THE TECHNICIAN DIAGNOSED THAT THE BLOWER MOTOR AND RELAY SWITCH NEEDED TO BE RE
Manufacturer communicationDate 2012-05-02
Blower Motor Inoperative After Control Module Replacement
2003 GMC YUKON +4 other vehicles / years
GM: BLOWER INOPERATIVE AFTER CONTROL MODULE REPLACEMENT. THIS MAY OCCUR IF THE SPEED IS SET TO ANY SPEED POSITION, EXCEPT FOR LOW, WHEN THE KEY IS TURNED OFF. UPON NEST KEY UP, THE BLOWER MOTOR MAY BE INOPERATIVE. ALSO INCLUDED MODEL CHEVRO
Manufacturer communicationDate 2012-04-10
Blower Motor Inoperativity with Key Off
2003 GMC YUKON、2003 GMC YUKON DENALI、2004 GMC YUKON … +41 other vehicles / years
BUICK/CADILLAC/CHEVROLET/GMC/OLDSMOBILE: IF BLOWER MOTOR IS SET TO ANY SPEED POSITION AND WHEN KEY IS OFF, IT BECOMES INOPERATIVE AND MAY STILL BE INOPERATIVE AFTER KEY IS TURNED ON. *PE UPDATED ON 5/1/12. *JS
Owner complaintDate 2012-01-17
Blower motor failure and rear door lock failure
2006 GMC YUKON
TL* THE CONTACT OWNS A 2006 GMC YUKON DENALI. THE CONTACT STATED THAT THE VEHICLE BLOWER MOTOR FAILED. THE BLOWER MOTOR CAUSED THE WINDSHIELD NOT TO BE ABLE TO DEFROST AND THE HEATHER TO FAIL. IN ADDITION, THE REAR DOOR LOCK FAILED AND COUL
Manufacturer communicationDate 2011-06-27
General Motors HVAC Blower Service Campaign
2003 GMC YUKON、2004 GMC YUKON、2005 GMC YUKON … +24 other vehicles / years
GENERAL MOTORS SERVICE CAMPAIGN: SEE DOCUMENT SEARCH BUTTON FOR OWNER LETTER. THE HVAC BLOWER MAY NOT WORK AT CERTAIN FUNCTIONS OR MAY BECOME INOPERABLE. THERE COULD BE A BURNING SMELL OR SMOKE. *RM UPDATED 4/6/12. *PE
Manufacturer communicationDate 2007-07-24
Front Blower Motor Inoperative or Not Shutting Off in Low Temperature
2004 GMC YUKON、2005 GMC YUKON、2006 GMC YUKON +27 other vehicles / years
FRONT BLOWER MOTOR INOPERATIVE OR MAY NOT SHUT OFF IN EXTREMELY LOW AMBIENT TEMPERATURE CONDITIONS. *KB
Manufacturer communicationDate 2005-11-04
Blower Motor Speed Loss Except High Speed or Inoperative
2004 GMC YUKON、2005 GMC YUKON、2006 GMC YUKON +16 other vehicles / years
EI05082 - LOSS OF BLOWER MOTOR SPEEDS EXCEPT FOR HIGH SPEED OR INOPERATIVE. *TT UPDATED. *KB UPDATED *KB
Manufacturer communicationDate 2005-10-25
Blower Motor Inoperative at Low Ambient Temperatures
2004 GMC YUKON、2005 GMC YUKON +12 other vehicles / years
BLOWER MOTOR INOPERATIVE AT LOW AMBIENT TEMPERATURES. *TT
Manufacturer communicationDate 2005-01-10
HVAC Blower Motor Inoperative or Stays Running
2003 GMC YUKON、2004 GMC YUKON、2005 GMC YUKON +21 other vehicles / years
HVAC BLOWER MOTOR INOPERATIVE OR STAYS RUNNING. *TT
Manufacturer communicationDate 2004-10-08
Repeat HVAC Blower Motor Failure
2003 GMC YUKON、2004 GMC YUKON +12 other vehicles / years
REPEAT HVAC BLOWER MOTOR FAILURE. *TT
Manufacturer communicationDate 2004-07-13
Fan blower motor continues to run after key off; A/C control head locking
2000 GMC YUKON、2001 GMC YUKON、2001 GMC YUKON DENALI … +5 other vehicles / years
THE FAN BLOWER MOTOR CONTINUES TO RUN AFTER THE KEY HAS BEEN TURNED OFF OR THE A/C CONTROL HEAD LOCKING UP. *TT
Manufacturer communicationDate 2003-12-01
HVAC Blower Motor May Run Continuously After Vehicle Is Turned Off
2004 GMC YUKON +5 other vehicles / years
HVAC BLOWER MOTOR MAY RUN CONTINUOUSLY AFTER VEHICLE IS TURNED OFF. *TT
Manufacturer communicationDate 2003-11-19
HVAC blower motor fan stays on in high blower position
2004 GMC YUKON、2004 GMC YUKON DENALI +6 other vehicles / years
HVAC BLOWER MOTOR FAN STAYS ON IN THE HIGH BLOWER POSITION. SERVICE VME. *TT