GMC Yukon 2000–2006
Common on this vehicle:Air conditioning or heaterSmoke or fire
Records
Owner complaint 0Recall 0Manufacturer communication 99 of 9 open without registering
Records per year (date of the record)
Manufacturer communication
2003200520102015202020252026
The 9 records listed below, each on its date (a dot opens its record)
2003-12-012012-05-02
Manufacturer communicationDate 2012-05-02
Blower Motor Inoperative After Control Module Replacement
2003 GMC YUKON +4 other vehicles / years
GM: BLOWER INOPERATIVE AFTER CONTROL MODULE REPLACEMENT. THIS MAY OCCUR IF THE SPEED IS SET TO ANY SPEED POSITION, EXCEPT FOR LOW, WHEN THE KEY IS TURNED OFF. UPON NEST KEY UP, THE BLOWER MOTOR MAY BE INOPERATIVE. ALSO INCLUDED MODEL CHEVRO
Manufacturer communicationDate 2012-04-10
Blower Motor Inoperativity with Key Off
2003 GMC YUKON、2003 GMC YUKON DENALI、2004 GMC YUKON … +41 other vehicles / years
BUICK/CADILLAC/CHEVROLET/GMC/OLDSMOBILE: IF BLOWER MOTOR IS SET TO ANY SPEED POSITION AND WHEN KEY IS OFF, IT BECOMES INOPERATIVE AND MAY STILL BE INOPERATIVE AFTER KEY IS TURNED ON. *PE UPDATED ON 5/1/12. *JS
Manufacturer communicationDate 2011-06-27
General Motors HVAC Blower Service Campaign
2003 GMC YUKON、2004 GMC YUKON、2005 GMC YUKON … +24 other vehicles / years
GENERAL MOTORS SERVICE CAMPAIGN: SEE DOCUMENT SEARCH BUTTON FOR OWNER LETTER. THE HVAC BLOWER MAY NOT WORK AT CERTAIN FUNCTIONS OR MAY BECOME INOPERABLE. THERE COULD BE A BURNING SMELL OR SMOKE. *RM UPDATED 4/6/12. *PE
Manufacturer communicationDate 2005-11-04
Blower Motor Speed Loss Except High Speed or Inoperative
2004 GMC YUKON、2005 GMC YUKON、2006 GMC YUKON +16 other vehicles / years
EI05082 - LOSS OF BLOWER MOTOR SPEEDS EXCEPT FOR HIGH SPEED OR INOPERATIVE. *TT UPDATED. *KB UPDATED *KB
Manufacturer communicationDate 2005-10-25
Blower Motor Inoperative at Low Ambient Temperatures
2004 GMC YUKON、2005 GMC YUKON +12 other vehicles / years
BLOWER MOTOR INOPERATIVE AT LOW AMBIENT TEMPERATURES. *TT
Manufacturer communicationDate 2005-01-10
HVAC Blower Motor Inoperative or Stays Running
2003 GMC YUKON、2004 GMC YUKON、2005 GMC YUKON +21 other vehicles / years
HVAC BLOWER MOTOR INOPERATIVE OR STAYS RUNNING. *TT
Manufacturer communicationDate 2004-10-08
Repeat HVAC Blower Motor Failure
2003 GMC YUKON、2004 GMC YUKON +12 other vehicles / years
REPEAT HVAC BLOWER MOTOR FAILURE. *TT
Manufacturer communicationDate 2004-07-13
Fan blower motor continues to run after key off; A/C control head locking
2000 GMC YUKON、2001 GMC YUKON、2001 GMC YUKON DENALI … +5 other vehicles / years
THE FAN BLOWER MOTOR CONTINUES TO RUN AFTER THE KEY HAS BEEN TURNED OFF OR THE A/C CONTROL HEAD LOCKING UP. *TT
Manufacturer communicationDate 2003-12-01
HVAC Blower Motor May Run Continuously After Vehicle Is Turned Off
2004 GMC YUKON +5 other vehicles / years
HVAC BLOWER MOTOR MAY RUN CONTINUOUSLY AFTER VEHICLE IS TURNED OFF. *TT