Skip to content
FaultCrate

This is an open preview: every record can be read without an account.

GMC YukonModel years 2000–2006

Change vehicle →

← All known issues

Fuel systemModel years 2003–2003Government

Mid-frame cross member tear could puncture fuel tank in angled frontal impact - recall 03V-019

Certain pickup trucks and sport utility vehicles; the NHTSA record lists GMC Yukon XL 2003. Model years come from the NHTSA record's product list held in the database, not from the recall text.

On certain pickup trucks and sport utility vehicles, in a 30 degree left angle frontal impact of sufficient severity, a tear could develop in the mid-frame cross member at its attachment to the left frame rail. A sharp edge from the tear contacting the fuel tank could puncture the tank with possible fuel leakage, which in the presence of an ignition source could result in a fire (NHTSA's recall summary).

How to decide

Install a fuel tank shield (the recall remedy)

Watch out

A cross member torn in a crash could puncture the tank: fuel leakage, possibly a fire

Parts

Fuel tank shield

Check1

  • The recall summary describes the vehicles only as certain pickup trucks and sport utility vehicles, naming no models or model years. GM's recall number is 03002.NHTSA

Decide2

The recall remedy: dealers install a fuel tank shield.NHTSA

  • The remedy is free; owner notification began February 20, 2003. Owners who take the vehicle to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time are directed to contact Chevrolet or GMC (NHTSA's Auto Safety Hotline can also be contacted).NHTSA

Steps

None of the documents at hand gives the manufacturer's procedure.

Cautions and risks1

  • If the mid-frame cross member tears in a 30 degree left angle frontal impact of sufficient severity and the sharp edge contacts the fuel tank, the tank could be punctured with possible fuel leakage, and with an ignition source present a fire could result.NHTSA

What it needs

Parts
  • A fuel tank shield (installed by the recall).NHTSA

Only what the documents and the pages read state; what is not listed is not thereby not needed.

If left

  • If the mid-frame cross member tears during frontal impact and produces a sharp edge, contact of the sharp edge with the fuel tank could result in a puncture of the fuel tank and possible fuel leakage.→ fuel tank puncture and fuel leakage
  • Fuel leakage in the presence of an ignition source could result in a fire.→ fire
See the evidence (1 documents, 4 passages)
DocumentPublisherDate
[1]Recall 03V019000: FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY ↗
GovernmentNHTSA
2003-01-27
  • Why it happensIn a sufficiently severe 30-degree left angle frontal impact, a tear could develop in the mid-frame cross member where it attaches to the left frame rail.

    DURING A 30 DEGREE LEFT ANGLE FRONTAL IMPACT OF SUFFICIENT SEVERITY, A TEAR COULD DEVELOP IN THE MID-FRAME CROSS MEMBER AT ITS ATTACHMENT TO THE LEFT FRAME RAIL.— [1]
  • If leftIf the mid-frame cross member tears during frontal impact and produces a sharp edge, contact of the sharp edge with the fuel tank could result in a puncture of the fuel tank and possible fuel leakage.

    IF THE MID-FRAME CROSS MEMBER TEARS DURING FRONTAL IMPACT AND PRODUCES A SHARP EDGE, CONTACT OF THE SHARP EDGE WITH THE FUEL TANK COULD RESULT IN A PUNCTURE OF THE FUEL TANK AND POSSIBLE FUEL LEAKAGE.— [1]
  • If leftFuel leakage in the presence of an ignition source could result in a fire.

    FUEL LEAKAGE, IN THE PRESENCE OF AN IGNITION SOURCE, COULD RESULT IN A FIRE.— [1]
  • RepairDealers install a fuel tank shield.

    DEALERS WILL INSTALL A FUEL TANK SHIELD.— [1]

Records under this issue 0

No record matches