Manufacturer communication — 2006 GMC YUKON DENALI XL

Fitment confirmedReporter type: ManufacturerVISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM

Relation to the target vehicle

  • The source's vehicle field includes the trim.
Model year
Match 2006 — Source vehicle field
Model
Match YUKON DENALI XL — Source vehicle field
Trim
Match Denali — Source vehicle field

What the manufacturer’s document says

PIT5099A ・ fault and correction ・ for GM vehicles in general

Applies to

  • Applies to 2015 and prior GM passenger cars and trucks.

    the passage
    2015 and Prior GM Passenger Cars and Trucks

Fault

  • The customer may comment that the A/C blows warm or performs poorly.

    the passage
    Customer may comment that there A/C blows warm or they have poor A/C performance.

Finding the cause

Steps to confirm (in the document’s order)

  1. Before calling GM TAC, have the A/C high and low pressures, the outside temperature, the humidity and the vent temperature available.

    the passage
    Please have the following information available: • A/C High and Low pressures • Outside temperature • Humidity • Vent temperature
  2. With an automatic HVAC system, read the inside, outside and duct temperature sensors, and the evaporator temperature sensor if equipped, from HVAC data with the scan tool.

    the passage
    If the unit is equipped with an Automatic HVAC system, go into the HVAC data with the scan tool and get the following readings: • Inside temperature sensor reading • Outside temperature sensor reading • Duct temperature sensor readings • Evaporator temperature sensor reading (if equipped)

Compiled by reading the full text of the document; each point stands on the passage shown. Check the document itself, linked below, before working on a vehicle.

Stated content

  1. Communication summary

    エアコンが温風を吹き出す、または性能が不良である。 Machine translation (unreviewed)

    A/C Blows Warm Or Poor Performance.