NHTSA Manufacturer Communications 10112935
原文と出典
原文
This Preliminary Information communication provides information to the technician about vehicles that have an OnStar system that will not power up. Technician should turn off the ignition and cancel retained accessory power. After the vehicle has powered down, remove power to the OnStar module for five minutes. After the power has been removed for five minutes, if the OnStar system is working release the vehicle. If the OnStar system is still inoperative continue with published Service Information diagnostics.
出典
- 情報源
- NHTSA Manufacturer Communications — メーカーがディーラーへ出した通知(行政機関が要約を公開)
- 報告者の区分
- メーカー
- 情報源での番号
- 10112935
- 国・市場
- US
- 言語
- en
- 文書版
- 第2版(保持2版)
- 情報源についての注記
- US federal government dataset of communications manufacturers sent to dealers. NHTSA publishes a summary of each communication, not its full text.
日時
- 発生日
- 不明
- 情報源の受付日
- 2017-08-15
- 情報源のファイルへの追加日
- 2017-08-15
- 発行・公表日
- 2013-03-25
- 初回観測
- 2026-10-05 11:21 JST (初回の一括取得)
- この版の取得
- 2026-10-05 12:49 JST