GMC Yukon XL 2000–2006
Common on this vehicle:Warning lightLeakNoiseCorrosion or rustStalls or shuts offVibration or shudderDoes not startGauge or instrument fault
Records
Owner complaint 4Recall 0Manufacturer communication 812 of 12 open without registering
Records per year (date of the record)
Owner complaintManufacturer communication
2001200520102015202020252026
The 12 records listed below, each on its date (a dot opens its record)
2001-12-012020-08-10
Manufacturer communicationDate 2020-08-10
Heater-Vent-Air Conditioning Blows Warm Air
2000 GMC YUKON XL、2001 GMC YUKON XL、2002 GMC YUKON XL … +49 other vehicles / years
Heater
This Preliminary Information communication provides information to the technician about vehicles that the Heater-Vent-Air Conditioning blows warm air. Before calling General Motors Technical Assistance Center technician will need to have hi
Manufacturer communicationDate 2018-11-13
Heater-Vent-Air Conditioning Blows Warm Air Information
2000 GMC YUKON XL、2001 GMC YUKON XL、2002 GMC YUKON XL … +49 other vehicles / years
Heater
This Preliminary Information communication provides information to the technician about vehicles that the Heater-Vent-Air Conditioning blows warm air. Before calling General Motors Technical Assistance Center technician will need to have hi
Manufacturer communicationDate 2018-08-06
Heater-Vent-Air Conditioning Blows Warm Air—Preliminary Information
2000 GMC YUKON XL、2001 GMC YUKON XL、2002 GMC YUKON XL … +49 other vehicles / years
Heater
This Preliminary Information communication provides information to the technician about vehicles that the Heater-Vent-Air Conditioning blows warm air. Before calling General Motors Technical Assistance Center technician will need to have hi
Manufacturer communicationDate 2018-05-07
Heater-Vent-Air Conditioning Warm Air Issue - Preliminary Information
2000 GMC YUKON XL、2001 GMC YUKON XL、2002 GMC YUKON XL … +49 other vehicles / years
Heater
This Preliminary Information communication provides information to the technician about vehicles that the Heater-Vent-Air Conditioning blows warm air. Before calling General Motors Technical Assistance Center technician will need to have hi
Manufacturer communicationDate 2017-12-22
Rear Window Defroster Contact or Tabs Service Information
2001 GMC YUKON XL、2002 GMC YUKON XL、2003 GMC YUKON XL … +55 other vehicles / years
defroster
This informational bulletin provide information for the technicians to repair the rear window defroster contact or tabs.
Owner complaintDate 2006-06-26
Battery leaks battery acid and causes corrosion, warranty denied
2002 GMC YUKON XL 1500
A/C
I AM CONCERNED THAT GMC IS NEGLECTING A SERIOUS ISSUE THAT COULD CAUSE CAR FIRES. I CALLED GMC 800)462-8782 AND SPOKE WITH STACY WHAPLES TODAY. SHE WAS NOT THE LEAST CONCERNED THAT THIS IS A REPEAT PROBLEM THAT COULD CAUSE SERIOUS INJURY.
Manufacturer communicationDate 2004-06-09
Rear Air Conditioning HVAC Blower Motor Control Module Information
2001 GMC YUKON XL DENALI、2002 GMC YUKON XL DENALI、2003 GMC YUKON XL DENALI +21 other vehicles / years
AIR CONDITIONING
REAR AIR CONDITIONING HVAC BLOWER MOTOR CONTROL MODULE INFORMATION. *TT
Owner complaintDate 2003-11-19
Fuel tank leaks when filled beyond 2/3-3/4 full
2002 GMC YUKON XL
HEATER
FUEL TANK LEAKS WHEN FILLED BEYOND 2/3-3/4 FULL. GAS TANK LEAKED GAS ON GARAGE FLOOR DAMAGING COATED/SEALED FLOOR. FORTUNATELY LEAKAGE WAS DISCOVERED BEFORE IT WAS ABLE TO IGNITE. VEHICLE WAS TAKEN TO DEALER AND I WAS ADVISED THAT IN FACT
Owner complaintDate 2003-05-20
Fuel leak in garage after filling gas tank on 2000 GMC Yukon XL
2002 GMC YUKON XL
HEATER
2000 GMC YUKON XL. FUEL LEAK IN MY GARAGE AFTER FILLING GAS TANK. LEAKED AT LEAST 6-8 GALLONS OF FUEL INTO GARAGE. SERVICE FACILITY DIAGNOSED PROBLEM TO BE FAULTY PLUNGER IN FUEL PUMP. VERY DANGEROUS, SINCE MY GARAGE CONTAINS GAS HOT WA
Owner complaintDate 2002-11-27
Front heater only operates at full temperature setting 82 degrees
2002 GMC YUKON XL
HEATER
FRONT HEATER ONLY OPERATES AT FULL TEMPERATURE SETTING 82 DEGREES. OTHERWISE, THE HEATER IS BLOWING COLD AIR, ABOUT THE OUTSIDE AIR TEMPERATURE. THE ONLY WAY TO REGULATE INSIDE TEMPERATURE IS TO SET AT 82 DEGREES, THEN TURN SYSTEM OFF UN
Manufacturer communicationDate 2002-01-01
Intermittent battery drain from a sticking A/C compressor relay
2000 GMC FULL SIZE PICKUPS AND UTILITY MODELS (YUKON XL)、2001 GMC FULL SIZE PICKUPS AND UTILITY MODELS (YUKON XL)、2002 GMC FULL SIZE PICKUPS AND UTILITY MODELS (YUKON XL) +3 other vehicles / years
A/C
Intermittent Battery Drain Owners of 2000-02 full size pickups and utility models may comment on an intermittent battery drain. This drain may occur overnight. The A/C compressor relay may stick causing the battery to drain. The current rec
Manufacturer communicationDate 2001-12-01
A/C not cold enough or blows warm at extended idle (6.0L): auxiliary electric cooling fan (bulletin 01-01-39-004)
2000 GMC C/K UTILITY MODELS (YUKON XL)、2001 GMC C/K UTILITY MODELS (YUKON XL)、2002 GMC C/K UTILITY MODELS (YUKON XL) +3 other vehicles / years
A/C
Bulletins – November 2001 01-01-39-004; A/C Not Cold Enough, A/C Blows Warm Air with Vehicle at Extended Idle (Install Auxiliary Electric Cooling Fan); 2000-02 Chevrolet and GMC C/K Utility Models, 2002 Cadillac Escalade, with 6.0L Engine (
