GMC Yukon 2000–2006
Common on this vehicle:Air conditioning or heaterLiftgate, rear glass or door lockSmoke or fire
Record by record
13 records state a cause or a remedy. Each record is shown as short labels in the order fault → finding the cause → correction. Press a label to narrow to the records that state it.
Component named as the cause
A ribbon is as wide as the records that state both of its ends (only the commonest are drawn). A record that names several symptoms or components runs through each. Orange is records that say the fault came back or was not fixed. Results come from owners’ reports only; one that does not say is “result not stated”. None of this is a likelihood of a cause or a rate at which work succeeds.
Read the records one by one (13)
EQUIPMENT4
Manufacturer communication2003–2006 GMC YUKON DENALI ・ 2012-04-10
Blower Motor Inoperativity with Key Off
1Fault
2Finding the cause
3Correction
Read the sentences of the record
- Remedy
- BUICK/CADILLAC/CHEVROLET/GMC/OLDSMOBILE: IF BLOWER MOTOR IS SET TO ANY SPEED POSITION AND WHEN KEY IS OFF, IT BECOMES INOPERATIVE AND MAY STILL BE INOPERATIVE AFTER KEY IS TURNED ON. *PE UPDATED ON 5/1/12. *JS
Manufacturer communication2004–2006 GMC YUKON ・ 2005-11-04
Blower Motor Speed Loss Except High Speed or Inoperative
1Fault
2Finding the cause
3Correction
Read the sentences of the record
- Remedy
- EI05082 - LOSS OF BLOWER MOTOR SPEEDS EXCEPT FOR HIGH SPEED OR INOPERATIVE. *TT UPDATED. *KB UPDATED *KB
Manufacturer communication2003–2004 GMC YUKON ・ 2004-10-08
Repeat HVAC Blower Motor Failure
1Fault
2Finding the cause
3Correction
Read the sentences of the record
- Remedy
- REPEAT HVAC BLOWER MOTOR FAILURE. *TT
Manufacturer communication2000–2002 GMC YUKON DENALI ・ 2004-07-13
Fan blower motor continues to run after key off; A/C control head locking
1Fault
2Finding the cause
3Correction
Read the sentences of the record
- Remedy
- THE FAN BLOWER MOTOR CONTINUES TO RUN AFTER THE KEY HAS BEEN TURNED OFF OR THE A/C CONTROL HEAD LOCKING UP. *TT
VISIBILITY4
Owner complaint2003 GMC YUKON ・ 2016-06-07
Blower motor stopped working while driving
1Fault
2Finding the cause
3CorrectionNot repaired
Read the sentences of the record
- Fault
- WHILE DRIVING 65 MPH (= 104.6 km/h), THE BLOWER MOTOR STOPPED WORKING WITHOUT WARNING.
- Remedy
- THE VEHICLE WAS NOT REPAIRED.
- Inspection
- THE TECHNICIAN DIAGNOSED THAT THE BLOWER MOTOR AND RELAY SWITCH NEEDED TO BE REPLACED.
Manufacturer communication2004–2005 GMC YUKON ・ 2005-10-25
Blower Motor Inoperative at Low Ambient Temperatures
1Fault
2Finding the cause
3Correction
Read the sentences of the record
- Remedy
- BLOWER MOTOR INOPERATIVE AT LOW AMBIENT TEMPERATURES. *TT
Manufacturer communication2003–2005 GMC YUKON ・ 2005-01-10
HVAC Blower Motor Inoperative or Stays Running
1Fault
2Finding the cause
3Correction
Read the sentences of the record
- Remedy
- HVAC BLOWER MOTOR INOPERATIVE OR STAYS RUNNING. *TT
Manufacturer communication2004 GMC YUKON ・ 2003-12-01
HVAC Blower Motor May Run Continuously After Vehicle Is Turned Off
1Fault
2Finding the cause
3Correction
HVAC BLOWER MOTOR MAY RUN CONTINUOUSLY AFTER VEHICLE IS TURNED OFF. *TT
Read the sentences of the record
- Remedy
- HVAC BLOWER MOTOR MAY RUN CONTINUOUSLY AFTER VEHICLE IS TURNED OFF. *TT
ELECTRICAL SYSTEM2
Owner complaint2006 GMC YUKON DENALI ・ 2018-09-05
Passenger side under-dash area caught fire while driving
1Fault
2Finding the cause
3Correction
Not stated
Read the sentences of the record
- Fault
- THE PASSENGER SIDE UNDER DASH BORED CAUGHT ON FIRE. (1 more)
- Cause
- I BELIEVE IT WAS THE MOTER BLOWER THAT SET ON FIRE DUE TO THATS WERE FIRE CAME FROM .AS WELL WHEN I LOOKED UNDER THE HOOD THERE WAS NOTHING WRONG WITH IT STILL PERFECT CONDITION.
Owner complaint2006 GMC YUKON ・ 2017-06-06
Air conditioner not operable and vehicle will not power off
1Fault
2Finding the cause
3Correction
Not stated
Read the sentences of the record
- Fault
- THE CONTACT STATED THAT THE AIR CONDITIONER IN THE FRONT OF THE VEHICLE WAS NOT OPERABLE. (2 more)
- Inspection
- THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC WHO DIAGNOSED THAT THE BLOWER MOTOR WAS DEFECTIVE AND NEEDED TO BE REPLACED.
ENGINE AND ENGINE COOLING2
Manufacturer communication2004–2006 GMC YUKON ・ 2007-07-24
Front Blower Motor Inoperative or Not Shutting Off in Low Temperature
1Fault
2Finding the cause
3Correction
Read the sentences of the record
- Remedy
- FRONT BLOWER MOTOR INOPERATIVE OR MAY NOT SHUT OFF IN EXTREMELY LOW AMBIENT TEMPERATURE CONDITIONS. *KB
Manufacturer communication2004 GMC YUKON DENALI ・ 2003-11-19
HVAC blower motor fan stays on in high blower position
1Fault
2Finding the cause
3Correction
HVAC BLOWER MOTOR FAN STAYS ON IN THE HIGH BLOWER POSITION. SERVICE VME. *TT
Read the sentences of the record
- Remedy
- HVAC BLOWER MOTOR FAN STAYS ON IN THE HIGH BLOWER POSITION. SERVICE VME. *TT
LATCHES/LOCKS/LINKAGES1
Owner complaint2006 GMC YUKON ・ 2012-01-17
Blower motor failure and rear door lock failure
1Fault
2Finding the cause
3CorrectionNot repaired
Read the sentences of the record
- Fault
- THE CONTACT STATED THAT THE VEHICLE BLOWER MOTOR FAILED. (1 more)
- Remedy
- THE VEHICLE WAS NOT REPAIRED.